EDH

A.O. Smith Water Heater

Severity: Moderate

What it means

A.O. Smith's hybrid electric heat pump water heater manuals (ProLine XE and Voltex) list EDH as: compressor discharge temperature is too high.
The Voltex manual words it as heat pump discharge temperature.

How to Fix It

  1. Press any button on the display to silence the alarm.

    A.O. Smith says an audible alarm may sound with this code.

  2. Call a qualified technician, or A.O. Smith's residential technical support.

    The heat pump's refrigerant circuit is technician work.
    The ProLine XE manual gives A.O. Smith's Technical Assistance Hotline as 1-800-527-1953.

Frequently Asked Questions

What do ECL, ECC, ECE and EEE mean?

ECL: heat pump suction pressure is too low; call a qualified technician.
ECC: the heat pump compressor is not functioning.
ECE: power supply error.
For ECC and ECE, the ProLine XE manual says to call the Technical Assistance Hotline.
EEE: EEPROM failure, a fault in the control's memory; turn the power off and on at the breaker first, and call the hotline if it stays.