EDH
A.O. Smith Water Heater
Severity: ModerateWhat it means
A.O. Smith's hybrid electric heat pump water heater manuals (ProLine XE and Voltex) list EDH as: compressor discharge temperature is too high.
The Voltex manual words it as heat pump discharge temperature.
How to Fix It
-
Press any button on the display to silence the alarm.
A.O. Smith says an audible alarm may sound with this code.
-
Call a qualified technician, or A.O. Smith's residential technical support.
The heat pump's refrigerant circuit is technician work.
The ProLine XE manual gives A.O. Smith's Technical Assistance Hotline as 1-800-527-1953.
Frequently Asked Questions
What do ECL, ECC, ECE and EEE mean?
ECL: heat pump suction pressure is too low; call a qualified technician.
ECC: the heat pump compressor is not functioning.
ECE: power supply error.
For ECC and ECE, the ProLine XE manual says to call the Technical Assistance Hotline.
EEE: EEPROM failure, a fault in the control's memory; turn the power off and on at the breaker first, and call the hotline if it stays.