Thermal Mode, Anti-freezing

Pentair Pool Pump

Severity: Minor

What it means

Thermal Mode (Anti-freezing on some models) means the pump's freeze protection is running. The motor runs at its preset speed until the drive's internal temperature rises above the minimum.
Pentair's IntelliFlo3 manual says Thermal Mode follows the drive's own temperature, not the water temperature. It is meant to keep the motor parts from freezing, and should not be the only freeze protection for the whole filtration system.
When the pump is connected to an automation system, its own thermal protection is turned off. Freeze protection then comes from setting ON WITH FREEZE to YES for the pump's circuit in the automation system.

How to Fix It

  1. Nothing needs fixing. Let the pump run: it stops once the drive has warmed up.

  2. On automation, check that the pump's circuit has ON WITH FREEZE set to YES. To turn the pump's own thermal protection back on after it has been disabled, switch the power to the drive off and on again.