Overheat, Drive is Derating, Derating Exceeded & Cut Off

Pentair Pool Pump

Severity: Moderate

What it means

Overheat means the drive temperature has gone above 130°F (54.4°C). The pump slowly reduces speed until the over temperature condition clears.
IntelliFlo3 VSF pumps add two messages. Drive is Derating is a warning that the pump is slowing down to keep the drive from overheating. Derating Exceeded & Cut Off is an alarm: slowing down was not enough, so the motor has stopped. Both clear by themselves once the drive has cooled.
Pentair gives the causes as a blocked cooling fan inlet or outlet, or very high air temperature around the pump.

How to Fix It

  1. Clean the fan guard on the motor. Pentair suggests compressed air to blow out dirt and debris.

  2. Clear leaves and debris from around the motor and give it more ventilation. If it sits in a hot enclosure, cooler air around it helps.

  3. If it keeps happening, have an electrician check for loose wiring and the right supply voltage. Pentair also lists a rubbing impeller as a reason for a motor running too hot.