Overheat, Drive is Derating, Derating Exceeded & Cut Off
Pentair Pool Pump
Severity: ModerateWhat it means
Overheat means the drive temperature has gone above 130°F (54.4°C). The pump slowly reduces speed until the over temperature condition clears.
IntelliFlo3 VSF pumps add two messages. Drive is Derating is a warning that the pump is slowing down to keep the drive from overheating. Derating Exceeded & Cut Off is an alarm: slowing down was not enough, so the motor has stopped. Both clear by themselves once the drive has cooled.
Pentair gives the causes as a blocked cooling fan inlet or outlet, or very high air temperature around the pump.
How to Fix It
-
Clean the fan guard on the motor. Pentair suggests compressed air to blow out dirt and debris.
-
Clear leaves and debris from around the motor and give it more ventilation. If it sits in a hot enclosure, cooler air around it helps.
-
If it keeps happening, have an electrician check for loose wiring and the right supply voltage. Pentair also lists a rubbing impeller as a reason for a motor running too hot.