Power Out, Under Voltage, Low Voltage
Pentair Pool Pump
Severity: ModerateWhat it means
Power Out (Power Out/OFF or Power out failure, by model) means the incoming supply voltage is less than 170 VAC. The drive faults to protect itself from over current. Pentair's IntelliFlo VSF chart also calls a low supply a Low Voltage alarm.
The drive keeps enough power in its capacitors to save its current settings. If the power comes back during that save, about 20 seconds, the drive finishes it before restarting.
IntelliFlo3 VSF pumps show Under Voltage: the supplied voltage is outside the proper range. The alert clears and the pump carries on when the voltage is back to normal.
How to Fix It
-
Check for a power cut or a tripped breaker. The pump restarts once the power is back.
-
If it happens with the power on, have an electrician check the voltage at the motor and at the panel while the pump runs, and look for loose connections. Pentair's limit is 90% to 110% of the rated voltage.