Over Voltage

Pentair Pool Pump

Severity: Moderate

What it means

Over Voltage means there is excessive supply voltage, or an external water source is turning the pump and motor. Either one puts too much voltage on the drive's internal DC bus.
The drive restarts by itself 20 seconds after the condition clears.
On the IntelliFlo3 VSF, Over Voltage means the supplied voltage is outside the proper range. The pump carries on once it is back to normal.

How to Fix It

  1. Look for anything that pushes water through the pump while it is off or running slowly, such as another pump on the same pipes. Pentair notes the pump will not start while its impeller is turning.

  2. Pentair's IntelliFlo 4 manual adds that switching rapidly between speeds can cause excessive voltage on the drive. Check any automation that changes the speed often.

  3. If it keeps happening, have a licensed electrician measure the line voltage. Pentair's limit is 90% to 110% of the rated voltage.